MOVING DIE RHEOMETER : HIWA 900

The HIWA 900 Rheometer is used for measuring the curing characteristics of rubber vs. time at constant temperature . In Hiwa 900 Rheometer , rubber paste is placed between dies under constant temperature and mechanical deformation is continuously applied to it by an oscillating die . The oscillation of die can be adjusted mechanically at angles ±0.5°, ±1°, ±3° . Before test execution , dies is heated up to predefined temperature . After placing of specimen , two die sealing plates are closed by a pnumatic cylinder. Rubber starts to cure and die starts to oscillate . The necessary torque for oscillating motion is increased gradually by curing of rubber paste . The magnitude of torque is measured by electronic system and simultaneously the torque - time curve is monitored by computer. After ending of test the two dies are opened by pnumatic cylinder and the cured specimen can be drawn out easily . The machine is fully controlled by a software via a computer attached to the machine . The software is so designed that training can be done in very short time and It is userfriendly. 

 

MDR Die

Specification : Models : 9010 & 9020
(Download Moving Die Rheometer Specification)
Standard : ISO 6502, ASTM D5289 
Type : MDR (Moving Die Rheometer) 
Die Oscillation angle : ±0.5°, ±1°, ±3° 
Measurement frequency 1.7±0.1 Hz 
Dim. of die : dia.=40 mm 
Temp. range : Ambient to 200°C 
Torque range : 0 - 200 lb -in 
Compressed air required 4-6 bar 
Operating Voltage 220 volt ,50-60 Hz 
Control Device fully contolled by computer 
Temperature display through computer & digitally 
Temperature Controller Fuzzy PID , 0.1°C 
Heating device Electrical heaters for upper die & lower die 
Pressure Display Analog Pressure gauge 
Heating Chamber for preventing the heat loss(over dies & cylinder) 
Computer CPU pentium IV or higher ,
17inch. LG monitor, 
Printer HP Laserjet 1018 
Software OS Windows 98SE , 2000 , XP 
Data Acquisition ,Monitoring Simultaneously 
Software Results Standard output (Updating by order) 
Model  9020 :
Ability to: 
Measurement of Viscous and damping characteristics of test specimen according to ASTM D6204 
(only calculation of variables) 
Other specification are same as model 9010 .